EX CFU-HT CABLE GLAND

Description

Ex CFU-HT type Hazardous Area Cable Gland Certified in Increased Safety (Type ‘eb’) & Dust Ignition Protection (Type ‘ta’) for use in Zone 1, 2, 20, 21 & 22 hazardous areas with all types of Armour cable providing an Environmental Seal on the cable Outer Sheath, also providing Mechanical Cable Retention & an Electrical Continuity via armour wire termination.This is a High Temperature Cable Gland

Technical Data
Type Ex CFU-HT (High Temperature)
Design Specification BS 6121: Part 1:1989, IEC 62444 : 2010 & EN 62444 : 2013
Mechanical Classification ** Retention = Class D, Impact = Level 8
Electrical Classification ** Category B
Enclosure Protection IK10 to IEC 62262 (20 Joule) Brass & Stainless Steel Only
Operating Temperature -55° C to + 175° C
Ingress Protection Rating IP 66 / IP 68***
Standard Gland Material Brass (BS EN 12164 / Grade CuZn39Pb3)
Seal Material Thermoset Elastomer
Standard Thread ISO Metric / NPT
Cable Type Wire Braid Armour, Strip Armour, Piliable Wire Armour, Steel Tape Armour, Single Wire Armour, Aluminium Wire Armour
Armour Clamping Detachable Armour Cone & Universal Armour Clamping Ring
Sealing Technique Load Retention Outer Seal
Sealing Area Cabel Outer Sheath
Optional Gland Material Brass Nickel Plated, Brass Electroless Nickel Plated, Stainless Steel (SS316 & SS316L)
Optional Accessories Adaptor, Reducer, Earth Tag, Lock Nut, Entry Thread Nylon & Fiber Washer, Serrated Washer, Shroud
Global Certification
Compliance Standards EN/IEC 60079-0, 1, 7, 31
ATEX Certificate DNV 22ATEX73142X
Code of Protection  | M2  || 2G 1D  2460, IP 66 / IP 68
IECEx Certificate IECEx DNV 22.0002X
Code of Protection Ex eb | Mb, Ex eb || C Gb, Ex ta ||| C Da
EAC Certificate Applied for Certificate
DNV GL Certificate Applied for Certificate
ABS Certificate Applied for Certificate
PESO Certificate A/P/HQ/GJ/104/6052 (P568100)
**Mechanical & Electrical Classification applied as per IEC / EN 62444 ***IP 68 : Tested at 30m depth for 7 days (Alternate depth & duration can be provided upon request)

Ex CFU-HT Cable Gland Selection Table

Gland Dimensions

Cable Dimensions

Cable Gland Size Entry Thread E Minimum Thread Length Maximum Length Across Flats Across Corners Cable Bedding Diameter Overall Cable Diameter Armour Range
Standard Option L1 L AF AC B A Direction 1 Direction 2
Metric NPT* NPT* Metric NPT Max Max Max Max Min Max Min Max Min Max
20S/16 M20 1/2″ 3/4″ 15.00 20.00 52.25 24.00 26.50 8.70 6.10 11.60 0.80 1.25 0.10 1.00
20S M20 1/2″ 3/4″ 15.00 20.00 52.25 24.00 26.50 11.70 9.50 16.00 0.80 1.25 0.10 1.00
20 M20 1/2″ 3/4″ 15.00 20.00 52.50 31.00 34.00 14.00 12.50 21.20 0.80 1.25 0.10 1.00
25S M25 3/4″ 1″ 15.00 20.50 64.00 37.50 41.25 16.00 14.10 22.00 1.25 1.60 0.10 1.00
25 M25 3/4″ 1″ 15.00 20.50 64.00 37.50 41.25 20.00 18.50 26.30 1.25 1.60 0.10 1.00
32 M32 1″ 1-1/4″ 15.00 25.50 65.50 46.00 50.50 26.40 24.00 34.00 1.60 2.00 0.10 1.00
40 M40 1-1/4″ 1-1/2″ 15.00 26.00 65.50 55.00 60.50 32.30 28.00 40.60 1.60 2.00 0.10 1.00
50S M50 1-1/2″ 2″ 15.00 26.50 72.50 60.00 66.00 38.50 35.50 46.70 2.00 2.50 0.10 1.00
50 M50 2″ 2-1/2″ 15.00 27.00 73.00 70.00 77.00 44.00 40.80 53.20 2.00 2.50 0.10 1.00
63S M63 2″ 2-1/2″ 15.00 27.00 73.50 75.00 82.50 50.00 45.70 59.40 2.00 2.50 0.10 1.00
63 M63 2-1/2″ 3″ 15.00 40.00 73.50 81.00 89.00 56.20 54.80 66.10 2.00 2.50 0.10 1.00
75S M75 2-1/2″ 3″ 15.00 40.00 82.50 91.00 100.00 62.00 59.50 72.20 2.00 2.50 0.10 1.00
75 M75 3″ 3-1/2″ 15.00 42.00 88.50 100.00 110.00 68.00 67.00 79.50 2.50 3.15 0.10 1.00
90 M90 3-1/2″ 4″ 20.00 43.00 95.50 114.00 125.25 80.00 75.00 90.50 2.75 3.50 0.10 1.00